  • Troubleshooting and repair of Taishan infrared burner

    2021-05-28 247

      Fan motor fault 

      Fan does not work, fan capacitor fault check, replace, repair air supply pipeline did not open the manual valve, open the air supply pipeline manual valve air pressure switch fault 

      Poor touch or damage of burning needle and thread leads to leakage inspection, isolation and repair

      The position of the burning rod is not adjusted properly, the burning interval is 4-6 mm, the burning controller is not checked, replaced and repaired, the fan works but does not burn, the air pressure switch is faulty, the fan volume is too large, the air volume share is adjusted, the burning is not successful, and the gas is not delivered

      1. There is something wrong with the solenoid valve

      2. Check, adjust and replace the blocked air supply pipeline, adjust the air volume share when the fan volume is too large, and touch the flame detection rod with the burning surface or the body of the incinerator.

    臺山紅外線燃燒器

      The gap between the flame detection rod and the burning surface is 6-10mm to ensure that there is no touch between the flame detection rod and the body of the incinerator. The orientation of the flame detection rod is bad, as above. The wire of the flame detection rod is bad. It is inappropriate to check and replace the air and gas share, adjust the air volume, adjust the outlet flow of the solenoid valve, and the burning controller is bad. 

           Article source: Taishan infrared burner  http://www.bjjx.org